Sign In | Join Free | My himfr.com
Home > Water Solenoid Valve >

Mini Water Solenoid Valve

    Buy cheap Mini Water Solenoid Valve from wholesalers
     
    Buy cheap Mini Water Solenoid Valve from wholesalers
    • Buy cheap Mini Water Solenoid Valve from wholesalers
    • Buy cheap Mini Water Solenoid Valve from wholesalers
    • Buy cheap Mini Water Solenoid Valve from wholesalers

    Mini Water Solenoid Valve

    Ask Lasest Price
    Brand Name : ROUND STAR
    Model Number : 2W
    Certification : ISO CE ROHS
    Price : USD
    Payment Terms : T/T, Western Union
    Supply Ability : ask for advice
    Delivery Time : 3~14 working days
    • Product Details
    • Company Profile

    Mini Water Solenoid Valve


    2W series 2-way direct acting ( NC ) solenoid valve 1/8" ~ 3/8"


    working medium:water,liquid,air,light oil(viscosity≤20cst)

    medium temperature:-5 ~ 80℃

    working pressure:0 ~ 15bar (details see specification table)

    working type:direct acting(NC)

    valvebody material:brass SS316

    sealing material:NBR

    interface:G thread NPT thread

    working voltage:AC220~240V AC110V 50/60Hz 22VA DC24V DC12V 13W IP65 H degree

    options:

    Rc thread sealing material: EPDM VITON VMQ

    digital timer LED light connector ES low power energy saving coil(AC220V 3VA DC24V 3W)



    2W-series 2-way direct acting(NC)specification table

    (ES coil can match EPDM and VITON, but medium temperature must be ≤80℃)

    Interface size

    Orifice size

    (mm)

    Cv


    working pressure(bar)

    medium

    temperature


    sealing

    material

    coil

    insulation

    degree


    coil powernormal order code

    min

    pressure

    max pressure pressure


    Normal coilEs coil

    plastic seal

    voltage AC220V

    G thread

    sealing material:Blank: NBR E:EPDM V:VITON


    air gas

    water hotwater

    liquid light oil

    VA


    W


    VA


    W


    AC

    220

    V

    DC

    24

    V

    AC

    220

    V

    DC

    24

    V

    ACDCbrassSS316

    1/8


    2.50.20151580NBRH2213332W-025-06N-AC220V2W-025-06JN-AC220V
    2.50.201515130EPDMH22132W-025-06N-E-AC220V2W-025-06JN-E-AC220V
    2.50.201515120VITONH22132W-025-06N-V-AC220V2W-025-06JN-V-AC220V
    3.00.250121280NBRH2213332W-030-06N-AC220V2W-030-06JN-AC220V
    3.00.2501212130EPDMH22132W-030-06N-E-AC220V2W-030-06JN-E-AC220V
    3.00.2501212120VITONH22132W-030-06N-V-AC220V2W-030-06JN-V-AC220V
    4.00.308580NBRH2213332W-040-06N-AC220V2W-040-06JN-AC220V
    4.00.3085130EPDMH22132W-040-06N-E-AC220V2W-040-06JN-E-AC220V
    4.00.3085120VITONH22132W-040-06N-V-AC220V2W-040-06JN-V-AC220V

    1/4


    2.50.20151580NBRH2213332W-025-08N-AC220V2W-025-08JN-AC220V
    2.50.201515130EPDMH22132W-025-08N-E-AC220V2W-025-08JN-E-AC220V
    2.50.201515120VITONH22132W-025-08N-V-AC220V2W-025-08JN-V-AC220V
    3.00.250121280NBRH2213332W-030-08N-AC220V2W-030-08JN-AC220V
    3.00.2501212130EPDMH22132W-030-08N-E-AC220V2W-030-08JN-E-AC220V
    3.00.2501212120VITONH22132W-030-08N-V-AC220V2W-030-08JN-V-AC220V
    4.00.308580NBRH2213332W-040-08N-AC220V2W-040-08JN-AC220V
    4.00.3085130EPDMH22132W-040-08N-E-AC220V2W-040-08JN-E-AC220V
    4.00.3085120VITONH22132W-040-08N-V-AC220V2W-040-08JN-V-AC220V
    1/45.00.405380NBRH2213332W-050-08N-AC220V2W-050-08JN-AC220V
    5.00.4053130EPDMH22132W-050-08N-E-AC220V2W-050-08JN-E-AC220V
    5.00.4053120VITONH22132W-050-08N-V-AC220V2W-050-08JN-V-AC220V
    6.00.704380NBRH2213332W-060-08N-AC220V2W-060-08JN-AC220V
    6.00.7043130EPDMH22132W-060-08N-E-AC220V2W-060-08JN-E-AC220V
    6.00.7043120VITONH22132W-060-08N-V-AC220V2W-060-08JN-V-AC220V

    3/8

    4.00.308580NBRH2213332W-040-10N-AC220V2W-040-10JN-AC220V
    4.00.3085130EPDMH22132W-040-10N-E-AC220V2W-040-10JN-E-AC220V
    4.00.3085120VITONH22132W-040-10N-V-AC220V2W-040-10JN-V-AC220V

    Water solenoid valve use and maintenance:
    1, it is recommended to use the unit to send the person responsible for maintenance.
    2, the solenoid valve is installed into the media need to pass several experimental action shall be put into use after confirming normal.
    3, large internal and external valve should be cleaned regularly and the title of the pull side of the dirt, careful not to damage the sealing surface.
    4, when the solenoid valve is a long time to do, should be closed before the valve manual valve, when re-enabled, steam solenoid valve should condensate removal and clean, and make trial action several times, only to be put into use after the switch to normal.
    5, when the solenoid valve from the pipeline do not remove, the internal parts should be scrubbed and blowing with compressed air storage.
    6, when used for a long time, such as a seal between the piston and the valve seat is bad, the piston sealing surface re-polished, and now seat grinding.
    7, in operation, should pay attention to before and after the valve pressure gauge required working pressure must not exceed the rated pressure, working pressure must be within the rated pressure range. When the operating pressure exceeds the rated pressure or working pressure exceeds the rated pressure, the solenoid valve to stop using closed before and after manual valves, solenoid valves to prevent explosions and leaks.

    Quality Mini Water Solenoid Valve for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Yuyao No. 4 Instrument Factory
    *Subject:
    *Message:
    Characters Remaining: (0/3000)